Skull X-Ray SMV

Skull Submentovertical VAR
Objective

Skull base and zygomatic arches.

Quality criteria

Skull base visible.
Zygomatic arches visible.
No rotation.

Common errors

Insufficient hyperextension.
Incorrect angulation.
Movement.

Paziente con testa in iperestensione massima. Vertice a contatto con il detettore. Piano infraorbitomeatale (IOML) parallelo al…

Full card in the app

Positioning, centring, DR/CR parameters and practical notes

Scarica su App StoreDisponibile su Google Play