Mandible X-Ray PA
Objective
Mandibular body and rami.
Quality criteria
Symmetrical visualisation of the mandibular body.
Mandibular rami included.
No rotation.
Common errors
Head rotation.
Superimposition of the cervical spine.
Movement.
Paziente in piedi o seduto. Fronte a contatto con il detettore. Allineamento simmetrico. Raggio centrale: angolato cranialmente…